Description
The Tramex Hygro-i2 relative humidity probe is the most advanced, resilient and reusable RH probe on the market today, allowing the user to perform in situ and hood type RH testing to comply with ASTM F2170 for the flooring industry. It is ideal for use by flood and water damage restoration and indoor air quality professionals. The speed and accuracy of the Tramex Hygro-i2 probes set them apart from all other RH probes on the market. The confidence in knowing you are testing with the best and fastest RH probe, together with the complete Tramex concrete moisture testing system, brings reliability and peace of mind in concrete moisture meters to a whole new level.
Used in conjunction with the Tramex CMEX5 and MEX5 non-destructive moisture meters, the older CMEX2 and MRH3 meters, or the Feedback Datalogger DL-RHTX, the Hygro-i2 probe provides measurements of relative humidity, temperature, dew point and grains per pound in structural materials such as concrete flooring and walls, as well as the ambient conditions within the building envelope, all shown simultaneously on one clear display.
The Hygro-i2 probes are reusable, paying for themselves after a few uses compared with single use, disposable RH probes. Calibration checks can be carried out using the SAL75 calibration check salts.
Please note that the RHIE2 Electronic Interface Cable is required to connect the Hygro-i2 probe to a meter or datalogger.
Features
- Fast acclimation time
- Reusable Hygro-i2 relative humidity sensors prove to be the lowest cost per ASTM F2170 test
- Best in class accuracy, even at high RH above 90%
- Proven robustness, durability and reliability
- Accurate, durable and best in class
- Testing per ASTM F2170, giving in situ relative humidity as well as ambient RH, temperature, dew point temperature and grains per pound
- Relative humidity range: 0% to 100%
- Fastest temperature response time
- Best temperature accuracy of plus or minus 0.1 degrees F
- Temperature range: -4 to 158 degrees F (-20 to 70 degrees C)
Applications
- In situ relative humidity testing of concrete floors and slabs to ASTM F2170 for the flooring industry
- Hood type surface RH testing
- Flood and water damage restoration
- Indoor air quality monitoring
- Monitoring moisture in structural materials such as concrete flooring and walls, and ambient conditions within the building envelope
Specifications
Relative Humidity Sensor
| Parameter | Value |
|---|---|
| Range | 0 to 100% RH |
| Accuracy | 0% to 99% RH, ±2.0% RH (at 77°F / 25°C) |
| Resolution | 0.1% over the complete range |
| Drift | Less than 0.25% RH per year |
Temperature Sensor
| Parameter | Value |
|---|---|
| Range | -4°F to 158°F (-20°C to 70°C) |
| Accuracy | ±0.1°F over range -4°F to 158°F (±0.1°C over range -20°C to 70°C) |
| Sensor protection | PTFE film protects sensor opening from water and dust |
| Drift | Less than 0.04°F (0.03°C) per year, NIST traceable |
Standards Referenced
- ASTM F2170
- BS 8201
- BS 8203
- BS 5325
- NIST traceable temperature calibration
Compatible Meters
Tramex CMEX5, MEX5, Feedback Datalogger DL-RHTX, and older meters CMEX2 and MRH3 (via RHIE2/RHIE2-B interface cable).
Additional information
| Tramex Hygro-i2 Relative Humidity Probe Pack Qty | Pack of 1, Pack of 3, Pack of 6, Pack of 12, Pack of 25, Pack of 50, Pack of 100 |
|---|
Reviews
There are no reviews yet.